Skip to content
RequestRoofA CLEARER WAY HOME
THE PLANNING DESK / 01

One roof.
A clearer plan.

Put the roof, solar and the numbers on the same page.

50 STATES + D.C.

Start with a working example. Replace every assumption with your measurements, utility terms and written quotes.

Explore incentive sources
Unsaved planning draft
Sign in to save
03 / BUILD THE OPTIONS

Roof now. Energy next?

Compare three scopes using the same roof. Add only a written coordination discount.

Electrical upgrades, permitting or other scope not included in the rate.

Optional. Replaces the rate calculation and extra-work allowance.

Default $0. Deducted once from each combined scenario.

For scope comparison. This planner does not estimate backup runtime.

Optional. Replaces the battery cost range.

04 / FIRST-YEAR ENERGY

Use your utility's numbers.

Enter annual production from an installer or PVWatts . No satellite, hourly or ZIP model runs here.

Starting value is an example, not an estimate for your address.

Add the last 12 months from your bills.

Before a battery; capped by annual household use. Confirm with interval data.

Variable energy charges only; fixed fees remain.

Use your actual tariff; do not assume full retail net metering.

Default zero. Enter a modeled value; capped by surplus solar and remaining household use.

Example assumption; use the installed system's value.

05 / CONFIRMED INCENTIVES

Count what's confirmed.

No automatic tax credit. Check eligibility, timing and eligible scope through the incentive finder, then record confirmed dollar amounts.

Use incremental amounts so the same program is not counted twice.

Only checked, documented amounts enter the net calculation; amounts are capped at each scenario's gross cost.

06 / PAYMENT

See the monthly commitment.

REQUESTROOF • PLANNING BRIEF
My roof + energy plan
Location: 
Illustrative planning model. Replace assumptions with written quotes. No automatic incentive or ZIP-based price adjustment.

ROOF GEOMETRY
Input 1800 ft² (footprint); pitch 6/12. Surface 2012.5 ft²; materials 2254.0 ft² including 12% waste.
Roof materials: $3,381 – $6,762 — 2,254 ft² including 12% waste × material rate
Installation labor: $4,025 – $8,050 — 2,012 ft² roof surface × labor rate
Access & complexity: $0 — 0% of installation labor
Tear-off: $2,012 — 1 layer(s) × surface area × removal rate
Decking allowance: $0 — 0 ft² × decking rate; confirm damaged area onsite
Roof permit allowance: $400 — Your entered allowance
Disposal allowance: $400 — Your entered allowance
Contingency: $1,022 – $1,762 — 10% of modeled roof subtotal

ROOF ONLY
Roof installed package: $11,240 – $19,387
Gross: $11,240 – $19,387
Confirmed incentives: $0
Net after confirmed incentives: $11,240 – $19,387
Modeled first-year energy value after maintenance: $0
Payment assumption: cash

ROOF + SOLAR
Roof installed package: $11,240 – $19,387
Solar installed package: $15,000 – $24,000
Confirmed combined-work discount: -$0
Gross: $26,240 – $43,387
Confirmed incentives: $0
Net after confirmed incentives: $26,240 – $43,387
Modeled first-year energy value after maintenance: $554
Payment assumption: cash

ROOF + SOLAR + BATTERY
Roof installed package: $11,240 – $19,387
Solar installed package: $15,000 – $24,000
Battery installed package: $10,000 – $18,000
Confirmed combined-work discount: -$0
Gross: $36,240 – $61,387
Confirmed incentives: $0
Net after confirmed incentives: $36,240 – $61,387
Modeled first-year energy value after maintenance: $554
Payment assumption: cash

INCENTIVES
No incentives confirmed.
ENERGY ASSUMPTIONS
Generation 8000 kWh/year; household use 12000 kWh/year; direct self-use 40%; retail $0.16/kWh; export $0.04/kWh; solar maintenance $150/year. Battery charge 0 kWh/year, efficiency 90%, maintenance $0/year.
Loan model uses gross less cash deposit, not future incentives. Deposit $0; annual interest 7%; term 10 years. Fees, escalation, degradation, replacements and tax effects are not modeled.

SITE REVIEW CHECKLIST
□ Roof life & condition — Record roof age, remaining service life, attachment details and who covers roof penetrations.
□ Shade & production — Request an hourly or annual shade assessment. Include trees, chimneys and seasonal shadows.
□ Direction & usable roof area — Have the installer model each usable roof plane, pitch, setbacks and obstructions. Direction alone does not establish suitability.
□ Structure & attachments — Have a qualified professional verify roof structure, attachment loads and local requirements. Save the review with your roof records.
□ Utility & electrical — Confirm the electrical-panel scope, interconnection process, export rate, fixed charges and permission to operate with the utility.
□ Permission & project coordination — Confirm ownership permissions, applicable HOA/local approvals, installer responsibilities and the roof/solar sequence.

NOTES
None entered.

METHOD
Surface = footprint × √(1 + (rise/12)²), or entered surface area. Waste applies only to materials; complexity applies only to labor. Quote overrides replace their whole package. Annual energy value = onsite kWh × retail rate + export kWh × export rate − maintenance. Battery charging is capped by surplus solar and remaining annual load; this is not an hourly dispatch or backup-runtime simulation.
Sources: https://www.energy.gov/cmei/systems/homeowners-guide-solar • https://pvwatts.nrel.gov/ • https://www.energy.gov/cmei/systems/solar-energy-guide-homebuilders